Channel Sabre Combined Optical & head ASD Multipoint Detectors

Channel

CHSASHPRO


Price:
Sale price £30.96 (£37.15 Inc VAT)

Description

Channel Sabre Combined Optical & head ASD Multipoint Detectors

The Channel Multipoint ASD detectors are a plug-in type smoke detector that utilises a photo-electric sensing chamber to make a measurement
corresponding to smoke density.

The device also incorporates a thermistor sensing circuit to allow for accurate heat measurement. These elements allow the device to be confi gured to a smoke, heat or combined setting. This device is only compatible with the Sabre Pro control panels (and their associated detection and alarm equipment) and may also incorporate a sounder beacon.

To ensure the detection capabilities of the detectors are never compromised they self-calibrate every 6 hours. They also continuously monitor for dust contamination until, depending on the environment, it reaches a point where the chamber becomes saturated. Before this can develop into a false alarm situation, the panel will indicate that the device in question requires attention.

FEATURES

  • 3 smoke detection modes
  • 3 heat detection modes - 2 fi xed, 1 rate-of-rise
  • Combination standard heat or smoke mode
  • When the detector head is removed, a base mounted LED fl ashes allowing users to easily identify which head is missing even from considerable distance, e.g. in a high-ceiling building
  • The Multipoint ASD detector incorporates a new advanced optical chamber for enhanced smoke detection
  • Flexible options/modes of fi re detection
  • Optional built-in sounder or sounder/strobe in a single device
  • Self-calibration every 6 hours
  • Continuous monitoring for dust contamination
  • Economical, disposable optical chamber for easy replacement
  • SPECIFICATIONS

  • Operating Temperature: -10° C to +50° C
  • Voltage Range 18 to 32V DC
  • Operating Current Quiescent - 109uA End of line ON if applicable - +50μA
  • (No strobe version) Alarm sounding - sounder high - 8.03mA | Alarm sounding - sounder low - 2.46mA |

  • Alarm sounding - sounder off - 143μA | Alarm activated - 15.54mA

    (Strobe version) Alarm sounding - sounder high - 10.54mA | Alarm sounding - sounder low - 4.92mA | Alarm sounding - sounder off - 2.58mA | Alarm activated - 17.92mA

  • Loading Max loading units per zone - 160 DLU
  • (No strobe version) Sounder high - 8.0 DLU | Sounder low - 2.5 DLU | No sounder - 0.5 DLU

    (Strobe version) Sounder high - 10.5 DLU | Sounder low - 5.0 DLU | No sounder - 3.0 DLU

  • Flammability: UL94-V2
  • LED Operation Detector in normal state (smoke) - fl ash at 20 second intervals
  • Detector in normal state (heat) - double fl ash at 20 second intervals. Detector at EOL - fl ash at 5 second intervals. Detector in fault - fl ash at 1.3 second intervals. Detector detecting fi re - fl ash at 0.7 seconds intervals.Detector in fi re (once processed at panel) - continuous.
  • IP Rating IP21C
  • Volume Level (@ 1m anechonic, dual tone) Sounder high - 90+dB(A) Sounder low - 70+dB(A)
  • Payment & Security

    American Express Apple Pay Diners Club Discover Google Pay Maestro Mastercard PayPal Shop Pay Visa

    Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.